        basic introduction

        ZRLK Laboratories is authorized to build professional laboratories in Shenzhen and Dongguan to provide "one-stop" services for testing and certification of small appliances.

        Product Range

        Household appliances, power tools, regulator controllers using semiconductor devices, electric motor-driven electrical appliances, medical equipment, electric toys, vending machines, and movie or slide projectors.

        Those not in scope are:

        In other standards, it clearly puts forward all emission requirements in the radio frequency range, such as lamps, power grid communication devices, etc .;

        Regulator controller equipped with semiconductor device with rated input current greater than 25A per phase and equipment with such controller;

        Power supply used alone.

        EU CE certification

        Electromagnetic compatibility directive: 2004/108 / EC

        Testing standards: EN55014-1 (EMI), EN55014-2 (EMS), EN61000-3-2 (Harmonic), EN61000-3-3 (Flicker)

        Note: The above EN 61000-3-2 and EN 61000-3-3 are applicable to the equipment where the input current per phase is less than 16A. If it is greater than 16A, EN 61000-3-12 and EN 61000-3-11 are applicable.

        EMI part

        Continuous harassment

        Terminal voltage:

        a Power terminal, frequency range: 0.15 ~ 30MHz; divided into two limits for household appliances / similar equipment and power tools

        b. Load terminal and additional terminal

        Harassment power:

        Frequency range 30M ~ 300MHz limit and 30M ~ 300MHz frequency range "Margin" limit (this limit is one of the basis for judging whether to measure radiation disturbance)

        Radiation harassment:

        The frequency range is 30MHz ~ 1GHz; when the following two conditions are met at the same time, you can not test this item:

        a. The measured value of the disturbance power is less than the above frequency range 30M ~ 300MHz limit minus the value of 30M ~ 300MHz frequency range "Margin";

        b. The maximum clock frequency is less than 30MHz. Otherwise, the project needs to be tested.

        Intermittent harassment

        Click:

        150KHz, 500KHz, 1.4MHz, 30MHz four frequency points, upper quartile judgment

        Harmonic current

        Standard: EN 61000-3-2

        Products with a rated voltage range of AC220 ~ 240V need to be tested in this project

        Products with a rated power of 75W and below have unlimited values, no test required

        Voltage fluctuation, flicker

        Standard: EN 61000-3-3

        Products with a rated voltage range of AC220 ~ 240V need to be tested in this project;

        Limit requirement: short-term flicker value Pst≤1.0

        Long-term flicker value Plt≤0.65

        The time d (t) ≤500ms during the voltage change exceeding 3.3%

        Relative steady-state voltage change dc≤3.3%

        The maximum corresponding voltage change dmax limit is divided into three types: 4%, 6%, 7%

        EMS part

        Product Categories

        Category 1: Appliances without electronic control circuits

        Category 2: Transformer toys with electronic control circuit, dual power supply toys, electric appliances powered by mains, electric tools, heating appliances and similar appliances (such as ultraviolet radiation meters, infrared radiation meters and microwave ovens). The internal clock frequency or oscillation frequency does not exceed 15MHz.

        Class 3: appliances with electronic control circuits and powered by batteries (built-in batteries or external batteries). Under normal use conditions, this type of appliance is not connected to the mains, and the internal clock frequency or oscillation frequency of its electronic control circuit does not exceed 15MHz.

        Category 4: All other appliances within the scope of this standard

        EMS performance criterion

        Performance criterion A

        During the test, the appliance should operate continuously as expected. When the appliance is used as intended, its performance degradation or loss of function is not allowed to fall below the performance level specified by the manufacturer (or tolerable performance loss). If the manufacturer does not specify a minimum performance level or a tolerable loss of performance, it can be inferred from the product specification, documentation, and the user's reasonable expectations of the appliance when it is expected to be used.

        Performance criterion B

        After the test, the appliance should continue to operate as expected. When the appliance is used as intended, its performance degradation or loss of function is not allowed to fall below the performance level specified by the manufacturer (or tolerable performance loss). During the test, performance degradation is allowed, but actual operating conditions or stored data are not allowed to change. If the manufacturer does not specify a minimum performance level or a tolerable loss of performance, it can be inferred from the product specification, documentation, and the user's reasonable expectations of the appliance when it is expected to be used.

        Performance criterion C

        Temporary loss of function is allowed, as long as this function can be recovered by itself, or by operating the controller or operating according to the instructions in the manual.

        American FCC certification

        Authentication form: FCCVerification

        Test standard: FCC 47CFR Part 15B

        Test items (only EMI part):

        Item    Frequency Range

        Power side conduction (CE)    0.15 ~ 30MHz

        Space radiation (RE)    30MHz ~ 1GHz

        Note: FCC certification, some household appliances can be exempted.

        China CCC certification

        Testing standards: GB4343.1, GB17625.1

        Test items:

        Terminal voltage    Frequency range: 0.15 ~ 30MHz

        Disturbance power    Frequency range 30M ~ 300MHz

        Radiated harassment    Frequency range 30MHz ~ 1GHz (only for toys, different from CE certification)

        Click sound    150K, 500K, 1.4M, 30MHz four frequency points

        Harmonic current    standard: GB17625.1

        Products with a rated voltage range of AC220 ~ 240V need to be tested for this project; products with a rated power of 75W and below have unlimited values and no testing is required.

        Australian RCM certification

        Testing standard: AS / NZSCISPR 14.1

        Test items:

        Terminal voltage    Frequency range: 0.15 ~ 30MHz

        Disturbance power    Frequency range 30M ~ 300MHz

        Radiated harassment    Frequency range 30MHz ~ 1GHz (Whether radiation measurement is the same as CE certification)

        Click sound    150K, 500K, 1.4M, 30MHz four frequency points

        Japan PSE certification

        Japan PSE certification: sub-diamond and round PSE

        Test standard: J55014-1

        Test items (only EMI part):

        Terminal voltage    Frequency range: 0.15 ~ 30MHz

        Disturbance power    Frequency range 30M ~ 300MHz

        Click sound   150K, 500K, 1.4M, 30MHz four frequency points

        Taiwan BSMI certification

        Detection standard: CNS13783-1

        Test items (only EMI part):

        Terminal voltage    Frequency range: 0.15 ~ 30MHz

        Disturbance power    Frequency range 30M ~ 300MHz

        Radiated harassment    Frequency range 30MHz ~ 1GHz (Whether radiation measurement is the same as CE certification)

        Click sound    150K, 500K, 1.4M, 30MHz four frequency points


        Online consultation

        Online consultation

        Recommend
        • Australian RCM certification

          Australian RCM certification

          Australian RCM certification

        • Label printer ANATEL certification

          Label printer ANATEL certification

          Label printers entering the Brazilian market, ANATEL certification is an essential passport! It is the recognition of the Brazilian Telecommunications Authority for the safety and compliance of electronic products, without which products cannot be legally sold.

        • Label printer SRRC certification

          Label printer SRRC certification

          SRRC certification is not only a guarantee of product compliance, but also a key to opening up the market.

        Household appliances testing and certification

        ZRLK Laboratories is authorized to build professional laboratories in Shenzhen and Dongguan to provide \"one-stop\" services for testing and certification of small appliances.

        Get a quote
        主站蜘蛛池模板: 精品国产成人国产在线视| 中国精品18videosex性中国| 国产一区二区丝袜美腿| 亚洲另类精品无码专区| 国产精品无码无卡在线播放| 亚洲三级香港三级久久| 亚洲无码色| 久久久久成人网站| 免费观看无码视频| 91超碰在线国产精品| 久久国模吧| 国产精品欧美福利久久| 天堂网亚洲综合在线| 人妻少妇精品无码专区app| 一本本月无码-| 久草网视频在线观看| 在线观看1024精品国产| 国产人与zoxxxx另类| 熟女精品国产一区二区三区| 开心一区二区三区激情| 韩国三级网一区二区三区| 人妻图区| 大帝AV在线一区二区三区| 久久久久人妻一区精品性色AV| 国内视频偷拍一区,二区,三区| 国内精品人妻一区二区三区| 色玖玖| 久久天堂av综合合色蜜桃网| 精品国内在视频线最新| 97青草香蕉依人在线视频| 一本色道久久综合亚洲精品不卡| 国产免费一区二区三区在线观看| 亚洲欧美另类久久久精品| 国产高清在线观看a| 美女黄18以下禁止观看| 久久亚洲国产欧洲精品一| 啪啪电影| 国产九九视频在线播放| 国产高清国内精品福利| 天天爱天天做天天爽夜夜揉 | 麻豆A∨在线|